Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Release characteristicK
Number of poles (total)3
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated voltage400V
Rated current1A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Pollution degree2
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings3
Power loss6W
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Over voltage category3
Current limiting class3
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
Explosion-proofNo
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-K1/3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Release characteristic

K

Number of poles (total)

3

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated voltage

400V

Rated current

1A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Pollution degree

2

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

3

Power loss

6W

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Over voltage category

3

Current limiting class

3

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Explosion-proof

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.