Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage400V
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated insulation voltage Ui440V
Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
Release characteristicK
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Built-in depth70.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Concurrently switching neutral conductorNo
Power loss14.8W
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationNo
Number of protected poles3
Rated current50A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Over voltage category3
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings3
Ambient temperature during operating-25 - 75°C
Pollution degree2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-K50/3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

400V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated insulation voltage Ui

440V

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV

Release characteristic

K

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Built-in depth

70.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Concurrently switching neutral conductor

Power loss

14.8W

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Number of protected poles

3

Rated current

50A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Over voltage category

3

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 75°C

Pollution degree

2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.