Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Number of protected poles3
Release characteristicC
Number of poles (total)4
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current50A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Current limiting class3
Over voltage category3
Frequency50 - 60Hz
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Width in number of modular spacings4
Power loss15W
Rated insulation voltage Ui440V
Pollution degree2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C50/3N

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Number of protected poles

3

Release characteristic

C

Number of poles (total)

4

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Rated current

50A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Current limiting class

3

Over voltage category

3

Frequency

50 .. 60Hz

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

4

Power loss

15W

Rated insulation voltage Ui

440V

Pollution degree

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Related products