Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated insulation voltage Ui440V
Rated current20A
Release characteristicK
Built-in depth70.5mm
Current limiting class3
Frequency50 - 60Hz
Rated voltage400V
Width in number of modular spacings4
Pollution degree2
Over voltage category3
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of poles (total)4
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-K20/3N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated insulation voltage Ui

440V

Rated current

20A

Release characteristic

K

Built-in depth

70.5mm

Current limiting class

3

Frequency

50 .. 60Hz

Rated voltage

400V

Width in number of modular spacings

4

Pollution degree

2

Over voltage category

3

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of poles (total)

4

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.