Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated voltage400V
Number of poles (total)4
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Power loss11.8W
Concurrently switching neutral conductorYes
Over voltage category3
Width in number of modular spacings4
Pollution degree2
Degree of protection (IP)IP20
Additional equipment possibleYes
Number of protected poles4
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated current32A
Release characteristicC
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Flush-mounted installationNo
Frequency50 - 60Hz
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C32/4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated voltage

400V

Number of poles (total)

4

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Power loss

11.8W

Concurrently switching neutral conductor

Over voltage category

3

Width in number of modular spacings

4

Pollution degree

2

Degree of protection (IP)

IP20

Additional equipment possible

Number of protected poles

4

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated current

32A

Release characteristic

C

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Flush-mounted installation

Frequency

50 .. 60Hz

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.