Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated insulation voltage Ui440V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Number of protected poles4
Rated current50A
Frequency50 - 60Hz
Voltage typeAC
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Release characteristicC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)4
Current limiting class3
Width in number of modular spacings4
Pollution degree2
Over voltage category3
Additional equipment possibleYes
Flush-mounted installationNo
Power loss15W
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Ambient temperature during operating-25 - 75°C
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C50/4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated insulation voltage Ui

440V

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

4

Rated current

50A

Frequency

50 .. 60Hz

Voltage type

AC

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Release characteristic

C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

4

Current limiting class

3

Width in number of modular spacings

4

Pollution degree

2

Over voltage category

3

Additional equipment possible

Flush-mounted installation

Power loss

15W

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Ambient temperature during operating

-25 .. 75°C

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA