Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage400V
Release characteristicK
Rated insulation voltage Ui440V
Built-in depth70.5mm
Frequency50 - 60Hz
Voltage typeAC
Rated current32A
Current limiting class3
Pollution degree2
Over voltage category3
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorYes
Number of poles (total)4
Width in number of modular spacings4
Power loss9.3W
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Additional equipment possibleYes
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 75°C
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-K32/4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

400V

Release characteristic

K

Rated insulation voltage Ui

440V

Built-in depth

70.5mm

Frequency

50 .. 60Hz

Voltage type

AC

Rated current

32A

Current limiting class

3

Pollution degree

2

Over voltage category

3

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Number of poles (total)

4

Width in number of modular spacings

4

Power loss

9.3W

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Additional equipment possible

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 75°C

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.