Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Current limiting class3
Over voltage category3
Voltage typeAC
Built-in depth75mm
Number of protected poles2
Connectable conductor cross section solid-core2.5 - 50mm²
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Number of poles (total)2
Rated voltage400V
Width in number of modular spacings3
Explosion-proofNo
Connectable conductor cross section multi-wired2.5 - 50mm²
Pollution degree2
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Release characteristicC
Flush-mounted installationNo
Rated current25A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-2-C25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Current limiting class

3

Over voltage category

3

Voltage type

AC

Built-in depth

75mm

Number of protected poles

2

Connectable conductor cross section solid-core

2.5 .. 50mm²

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Number of poles (total)

2

Rated voltage

400V

Width in number of modular spacings

3

Explosion-proof

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Pollution degree

2

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Release characteristic

C

Flush-mounted installation

Rated current

25A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.