Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated voltage400V
Rated current25A
Built-in depth75mm
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationNo
Number of poles (total)3
Over voltage category3
Degree of protection (IP)IP20
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Width in number of modular spacings4.5
Release characteristicC
Explosion-proofNo
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core2.5 - 50mm²
Number of protected poles3
Connectable conductor cross section multi-wired2.5 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-3-C25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated voltage

400V

Rated current

25A

Built-in depth

75mm

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Number of poles (total)

3

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Width in number of modular spacings

4.5

Release characteristic

C

Explosion-proof

Additional equipment possible

Concurrently switching neutral conductor

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

2.5 .. 50mm²

Number of protected poles

3

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C