Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75mm
Rated voltage400V
Voltage typeAC
Rated current40A
Degree of protection (IP)IP20
Frequency50 - 60Hz
Number of protected poles3
Release characteristicC
Width in number of modular spacings4.5
Over voltage category3
Rated insulation voltage Ui440V
Current limiting class3
Pollution degree2
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Connectable conductor cross section multi-wired2.5 - 50mm²
Connectable conductor cross section solid-core2.5 - 50mm²
Concurrently switching neutral conductorNo
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-3-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Rated voltage

400V

Voltage type

AC

Rated current

40A

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Number of protected poles

3

Release characteristic

C

Width in number of modular spacings

4.5

Over voltage category

3

Rated insulation voltage Ui

440V

Current limiting class

3

Pollution degree

2

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Connectable conductor cross section solid-core

2.5 .. 50mm²

Concurrently switching neutral conductor

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Related products