Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)3
Release characteristicD
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated insulation voltage Ui440V
Built-in depth75mm
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Pollution degree2
Over voltage category3
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Rated current80A
Current limiting class3
Voltage typeAC
Width in number of modular spacings4.5
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired2.5 - 50mm²
Explosion-proofNo
Connectable conductor cross section solid-core2.5 - 50mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-3-D80

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

3

Release characteristic

D

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated insulation voltage Ui

440V

Built-in depth

75mm

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Pollution degree

2

Over voltage category

3

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Rated current

80A

Current limiting class

3

Voltage type

AC

Width in number of modular spacings

4.5

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Explosion-proof

Connectable conductor cross section solid-core

2.5 .. 50mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.