Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75mm
Voltage typeAC
Ambient temperature during operating-25 - 55°C
Rated voltage400V
Rated insulation voltage Ui440V
Additional equipment possibleYes
Pollution degree2
Current limiting class3
Rated current80A
Over voltage category3
Number of poles (total)4
Connectable conductor cross section multi-wired2.5 - 50mm²
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Connectable conductor cross section solid-core2.5 - 50mm²
Number of protected poles3
Explosion-proofNo
Width in number of modular spacings6
Release characteristicD
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-3N-D80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Voltage type

AC

Ambient temperature during operating

-25 .. 55°C

Rated voltage

400V

Rated insulation voltage Ui

440V

Additional equipment possible

Pollution degree

2

Current limiting class

3

Rated current

80A

Over voltage category

3

Number of poles (total)

4

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Connectable conductor cross section solid-core

2.5 .. 50mm²

Number of protected poles

3

Explosion-proof

Width in number of modular spacings

6

Release characteristic

D

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated impulse withstand voltage Uimp

4kV