Aleta.hr

Details

  • Low-voltage industrial components
  • Power contactor, AC switching
  • 1 KOM
  • EATON

Technical specifications

Depth75mm
Modular versionNo
Height68mm
Width45mm
Rated control supply voltage Us at AC 60HZ48 - 48V
Number of normally open contacts as main contact3
Rated operation current Ie at AC-3, 400 V9A
Rated operation power at AC-3, 400 V4kW
Operating voltage at AC 60 Hz24 - 690V
Voltage type for actuatingAC
Rated operation current Ie at AC-1, 400 V22A
Number of auxiliary contacts as normally open contact1
Type of electrical connection of main circuitScrew connection
Rated operation power NEMA3.7kW
Rated control supply voltage Us at DC0 - 0V
Number of normally closed contacts as main contact0
Rated operation current Ie at AC-4, 400 V6A
Rated operation power at AC-4, 400 V2.5kW
Rated control supply voltage Us at AC 50HZ42 - 42V
Number of auxiliary contacts as normally closed contact0
Operating voltage at AC 50 Hz24 - 690V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DILM9-10(42V50HZ,48V60HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power contactor, AC switching
  • 1 KOM
  • EATON

Technical specifications

Depth

75mm

Modular version

Height

68mm

Width

45mm

Rated control supply voltage Us at AC 60HZ

48 .. 48V

Number of normally open contacts as main contact

3

Rated operation current Ie at AC-3, 400 V

9A

Rated operation power at AC-3, 400 V

4kW

Operating voltage at AC 60 Hz

24 .. 690V

Voltage type for actuating

AC

Rated operation current Ie at AC-1, 400 V

22A

Number of auxiliary contacts as normally open contact

1

Type of electrical connection of main circuit

Screw connection

Rated operation power NEMA

3.7kW

Rated control supply voltage Us at DC

0 .. 0V

Number of normally closed contacts as main contact

0

Rated operation current Ie at AC-4, 400 V

6A

Rated operation power at AC-4, 400 V

2.5kW

Rated control supply voltage Us at AC 50HZ

42 .. 42V

Number of auxiliary contacts as normally closed contact

0

Operating voltage at AC 50 Hz

24 .. 690V