  • Low-voltage industrial components
  • Power contactor, AC switching
  • 1 KOM
  • EATON

Technical specifications

Modular versionNo
Number of normally open contacts as main contact3
Number of normally closed contacts as main contact0
Height189mm
Depth208mm
Rated operation power at AC-3, 400 V132kW
Width140mm
Rated operation current Ie at AC-4, 400 V200A
Rated operation power NEMA149kW
Rated operation current Ie at AC-1, 400 V429A
Rated operation current Ie at AC-3, 400 V250A
Rated control supply voltage Us at DC110 - 250V
Rated control supply voltage Us at AC 50HZ110 - 250V
Voltage type for actuatingAC/DC
Operating voltage at AC 50 Hz110 - 250V
Number of auxiliary contacts as normally open contact2
Rated control supply voltage Us at AC 60HZ110 - 250V
Type of electrical connection of main circuitRail connection
Operating voltage at AC 60 Hz110 - 250V
Rated operation power at AC-4, 400 V110kW
Number of auxiliary contacts as normally closed contact2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DILM250/22(RA250)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power contactor, AC switching
  • 1 KOM
  • EATON

Technical specifications

Modular version

Number of normally open contacts as main contact

3

Number of normally closed contacts as main contact

0

Height

189mm

Depth

208mm

Rated operation power at AC-3, 400 V

132kW

Width

140mm

Rated operation current Ie at AC-4, 400 V

200A

Rated operation power NEMA

149kW

Rated operation current Ie at AC-1, 400 V

429A

Rated operation current Ie at AC-3, 400 V

250A

Rated control supply voltage Us at DC

110 .. 250V

Rated control supply voltage Us at AC 50HZ

110 .. 250V

Voltage type for actuating

AC/DC

Operating voltage at AC 50 Hz

110 .. 250V

Number of auxiliary contacts as normally open contact

2

Rated control supply voltage Us at AC 60HZ

110 .. 250V

Type of electrical connection of main circuit

Rail connection

Operating voltage at AC 60 Hz

110 .. 250V

Rated operation power at AC-4, 400 V

110kW

Number of auxiliary contacts as normally closed contact

2