  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated current20A
Release characteristicB
Connectable conductor cross section solid-core1 - 25mm²
Rated insulation voltage Ui440V
Rated voltage400V
Degree of protection (IP)IP20
Voltage typeAC
Over voltage category3
Width in number of modular spacings4
Current limiting class3
Concurrently switching neutral conductorYes
Number of protected poles3
Connectable conductor cross section multi-wired1 - 25mm²
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Number of poles (total)4
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated impulse withstand voltage Uimp4kV

Related products


Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL6-C20/3N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated current

20A

Release characteristic

B

Connectable conductor cross section solid-core

1 .. 25mm²

Rated insulation voltage Ui

440V

Rated voltage

400V

Degree of protection (IP)

IP20

Voltage type

AC

Over voltage category

3

Width in number of modular spacings

4

Current limiting class

3

Concurrently switching neutral conductor

Number of protected poles

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Number of poles (total)

4

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV