Technical specifications

Number of protected poles2
Voltage typeDC
Rated current3A
Width in number of modular spacings2
Built-in depth70.5mm
Degree of protection (IP)IP20
Release characteristicC
Current limiting class3
Frequency0 - 0Hz
Over voltage category3
Pollution degree2
Rated insulation voltage Ui440V
Rated voltage220V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Connectable conductor cross section solid-core1 - 25mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-C3/2-DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

2

Voltage type

DC

Rated current

3A

Width in number of modular spacings

2

Built-in depth

70.5mm

Degree of protection (IP)

IP20

Release characteristic

C

Current limiting class

3

Frequency

0 .. 0Hz

Over voltage category

3

Pollution degree

2

Rated insulation voltage Ui

440V

Rated voltage

220V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Connectable conductor cross section solid-core

1 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor