Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu20A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting15 - 20A
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Number of poles3
Adjustment range undelayed short-circuit release350 - 350A
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Type of control elementRocker lever
Integrated earth fault protectionNo
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release0 - 0A
Rated voltage1000 - 1000V
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A20-S1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

20A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

15 .. 20A

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of poles

3

Adjustment range undelayed short-circuit release

350 .. 350A

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Type of control element

Rocker lever

Integrated earth fault protection

With integrated under voltage release

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive integrated

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated voltage

1000 .. 1000V

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Related products