Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu160A
Adjustment range undelayed short-circuit release960 - 1600A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Rated voltage1000 - 1000V
Number of auxiliary contacts as change-over contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Type of control elementRocker lever
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Motor drive optionalYes
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting125 - 160A
Complete device with protection unitYes
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A160-S1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Adjustment range undelayed short-circuit release

960 .. 1600A

Position of connection for main current circuit

Front side

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Rated voltage

1000 .. 1000V

Number of auxiliary contacts as change-over contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Type of control element

Rocker lever

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Motor drive optional

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

125 .. 160A

Complete device with protection unit

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP20

Related products