Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu1000A
Overload release current setting500 - 1000A
Rated voltage1000 - 1000V
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
With integrated under voltage releaseNo
Adjustment range short-term delayed short-circuit release0 - 0A
Type of control elementRocker lever
Number of poles3
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release2000 - 12000A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH4-AE1000-S1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

1000A

Overload release current setting

500 .. 1000A

Rated voltage

1000 .. 1000V

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Motor drive optional

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

With integrated under voltage release

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of control element

Rocker lever

Number of poles

3

Complete device with protection unit

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

2000 .. 12000A

Related products