Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu800A
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release800 - 8000A
Rated voltage1000 - 1000V
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Number of poles3
Complete device with protection unitYes
Motor drive optionalYes
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device fixed built-in technique
Overload release current setting400 - 800A
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Adjustment range undelayed short-circuit release1600 - 9600A
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
With switched-off indicatorNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH4-VE800-S1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

800A

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Rated voltage

1000 .. 1000V

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Complete device with protection unit

Motor drive optional

Type of control element

Rocker lever

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device fixed built-in technique

Overload release current setting

400 .. 800A

With integrated under voltage release

Degree of protection (IP)

IP20

Adjustment range undelayed short-circuit release

1600 .. 9600A

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

With switched-off indicator