Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Number of poles3
Type of control elementRocker lever
Rated permanent current Iu40A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Overload release current setting32 - 40A
Type of electrical connection of main circuitFrame clamp
Motor drive optionalNo
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release320 - 400A
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
Complete device with protection unitYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes

Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LZMC1-A40-I

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of poles

3

Type of control element

Rocker lever

Rated permanent current Iu

40A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Overload release current setting

32 .. 40A

Type of electrical connection of main circuit

Frame clamp

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

320 .. 400A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

Complete device with protection unit

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

From same serie

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.