Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current at AC-23, 400 V-A
Number of switches-
Version as maintenance-/service switchYes
Version as main switchYes
Max. rated operation voltage Ue AC400V
Rated permanent current at AC-21, 400 V0A
Rated permanent current Iu160A
Version as safety switchNo
Version as emergency stop installationYes
Version as reversing switchNo
Rated operating voltage690 - 690V
Rated short-time withstand current lcw2kA
Conditioned rated short-circuit current Iq100kA
Switching power at 400 V0kW
Number of auxiliary contacts as normally closed contact0
Number of poles3
Suitable for front mounting 4-holeNo
Device constructionBuilt-in device fixed built-in technique
Suitable for distribution board installationYes
Rated operation power at AC-3, 400 V0kW
Suitable for front mounting centreNo
Rated operation power at AC-23, 400 V90kW
Colour control elementGrey
Number of auxiliary contacts as normally open contact0
InterlockableYes
Type of control elementRocker lever
Motor drive optionalYes
With pre-assembled cablingNo
Suitable for floor mountingYes
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as change-over contact0
Suitable for intermediate mountingYes
Degree of protection (IP), front sideIP20
Depth88mm
Width90mm
Height145mm
Motor drive integratedNo
Voltage release optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LN1-160-I

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current at AC-23, 400 V

-A

Number of switches

-

Version as maintenance-/service switch

Version as main switch

Max. rated operation voltage Ue AC

400V

Rated permanent current at AC-21, 400 V

0A

Rated permanent current Iu

160A

Version as safety switch

Version as emergency stop installation

Version as reversing switch

Rated operating voltage

690 .. 690V

Rated short-time withstand current lcw

2kA

Conditioned rated short-circuit current Iq

100kA

Switching power at 400 V

0kW

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Suitable for front mounting 4-hole

Device construction

Built-in device fixed built-in technique

Suitable for distribution board installation

Rated operation power at AC-3, 400 V

0kW

Suitable for front mounting centre

Rated operation power at AC-23, 400 V

90kW

Colour control element

Grey

Number of auxiliary contacts as normally open contact

0

Interlockable

Type of control element

Rocker lever

Motor drive optional

With pre-assembled cabling

Suitable for floor mounting

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as change-over contact

0

Suitable for intermediate mounting

Degree of protection (IP), front side

IP20

Depth

88mm

Width

90mm

Height

145mm

Motor drive integrated

Voltage release optional

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.