Width515mm
Voltage type for actuatingAC/DC
Modular versionNo
Rated operation power at AC-4, 400 V750kW
Rated control supply voltage Us at AC 60HZ230 - 250V
Height252mm
Operating voltage at AC 60 Hz230 - 250V
Type of electrical connection of main circuitRail connection
Number of normally open contacts as main contact3
Depth392mm
Rated control supply voltage Us at DC230 - 250V
Rated operation power NEMA895kW
Rated operation current Ie at AC-1, 400 V2200A
Rated operation current Ie at AC-4, 400 V1280A
Operating voltage at AC 50 Hz230 - 250V
Number of normally closed contacts as main contact0
Rated operation power at AC-3, 400 V900kW
Number of auxiliary contacts as normally open contact2
Number of auxiliary contacts as normally closed contact2
Rated operation current Ie at AC-3, 400 V1600A
Rated control supply voltage Us at AC 50HZ230 - 250V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DILM1600/22(RAW250)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power contactor, AC switching
  • 1 KOM
  • EATON

Technical specifications

Width

515mm

Voltage type for actuating

AC/DC

Modular version

Rated operation power at AC-4, 400 V

750kW

Rated control supply voltage Us at AC 60HZ

230 .. 250V

Height

252mm

Operating voltage at AC 60 Hz

230 .. 250V

Type of electrical connection of main circuit

Rail connection

Number of normally open contacts as main contact

3

Depth

392mm

Rated control supply voltage Us at DC

230 .. 250V

Rated operation power NEMA

895kW

Rated operation current Ie at AC-1, 400 V

2200A

Rated operation current Ie at AC-4, 400 V

1280A

Operating voltage at AC 50 Hz

230 .. 250V

Number of normally closed contacts as main contact

0

Rated operation power at AC-3, 400 V

900kW

Number of auxiliary contacts as normally open contact

2

Number of auxiliary contacts as normally closed contact

2

Rated operation current Ie at AC-3, 400 V

1600A

Rated control supply voltage Us at AC 50HZ

230 .. 250V