Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
200A
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Rated operating voltage
690 - 690V
Number of switches
1
Rated permanent current at AC-21, 400 V
0A
Version as reversing switch
No
Version as safety switch
No
Rated permanent current at AC-23, 400 V
0A
Max. rated operation voltage Ue AC
690V
Rated short-time withstand current lcw
3.5kA
Rated operation power at AC-23, 400 V
110kW
Switching power at 400 V
0kW
Rated operation power at AC-3, 400 V
0kW
Version as emergency stop installation
Yes
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
0kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
No
Motor drive optional
Yes
Voltage release optional
Yes
Device construction
Built-in device plug-in technique
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Suitable for distribution board installation
Yes
Suitable for intermediate mounting
Yes
Colour control element
Black
Type of control element
Rocker lever
Interlockable
Yes
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
No
Degree of protection (IP), front side
IP20
Width
140mm
Height
245mm
Depth
180mm
Related products
N2-4-200-SVE

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
200A
Version as maintenance-/service switch
Version as main switch
Rated operating voltage
690 .. 690V
Number of switches
1
Rated permanent current at AC-21, 400 V
0A
Version as reversing switch
Version as safety switch
Rated permanent current at AC-23, 400 V
0A
Max. rated operation voltage Ue AC
690V
Rated short-time withstand current lcw
3.5kA
Rated operation power at AC-23, 400 V
110kW
Switching power at 400 V
0kW
Rated operation power at AC-3, 400 V
0kW
Version as emergency stop installation
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
0kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
Motor drive optional
Voltage release optional
Device construction
Built-in device plug-in technique
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for front mounting centre
Suitable for distribution board installation
Suitable for intermediate mounting
Colour control element
Black
Type of control element
Rocker lever
Interlockable
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
Degree of protection (IP), front side
IP20
Width
140mm
Height
245mm
Depth
180mm
Related products