Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu160A
Adjustment range undelayed short-circuit release6 - 10A
Rated voltage440 - 440V
Device constructionBuilt-in device plug-in technique
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
With switched-off indicatorNo
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting125 - 160A
Number of poles4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Type of control elementRocker lever
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB2-4-A160-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Adjustment range undelayed short-circuit release

6 .. 10A

Rated voltage

440 .. 440V

Device construction

Built-in device plug-in technique

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

With switched-off indicator

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

125 .. 160A

Number of poles

4

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Type of control element

Rocker lever

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20