Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage440 - 440V
Overload release current setting200 - 250A
Rated permanent current Iu250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release1500 - 2500A
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Type of control elementRocker lever
Number of poles3
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
With switched-off indicatorNo
Device constructionBuilt-in device plug-in technique

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB2-A250-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

440 .. 440V

Overload release current setting

200 .. 250A

Rated permanent current Iu

250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

1500 .. 2500A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Type of control element

Rocker lever

Number of poles

3

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20

With switched-off indicator

Device construction

Built-in device plug-in technique

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.