Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Integrated earth fault protectionNo
Rated voltage690 - 690V
Device constructionBuilt-in device plug-in technique
Adjustment range undelayed short-circuit release6 - 10A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release0 - 0A
Number of poles4
Complete device with protection unitYes
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu100A
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Overload release current setting80 - 100A
Motor drive integratedNo
Degree of protection (IP)IP20
With switched-off indicatorNo
Type of control elementRocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-A100-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Integrated earth fault protection

Rated voltage

690 .. 690V

Device construction

Built-in device plug-in technique

Adjustment range undelayed short-circuit release

6 .. 10A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of poles

4

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

100A

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Overload release current setting

80 .. 100A

Motor drive integrated

Degree of protection (IP)

IP20

With switched-off indicator

Type of control element

Rocker lever