Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated voltage690 - 690V
Overload release current setting80 - 100A
Rated permanent current Iu100A
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device plug-in technique
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Number of poles3
Adjustment range undelayed short-circuit release600 - 1000A
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Motor drive integratedNo
Type of control elementRocker lever
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A100-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated voltage

690 .. 690V

Overload release current setting

80 .. 100A

Rated permanent current Iu

100A

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device plug-in technique

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Number of poles

3

Adjustment range undelayed short-circuit release

600 .. 1000A

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Motor drive integrated

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Motor drive optional

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.