Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting50 - 63A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release380 - 630A
Rated permanent current Iu63A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
Number of poles3
With switched-off indicatorNo
Complete device with protection unitYes
Motor drive integratedNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A63-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

50 .. 63A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

380 .. 630A

Rated permanent current Iu

63A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Motor drive optional

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

Number of poles

3

With switched-off indicator

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP20

Related products