Technical specifications

Adjustment range undelayed short-circuit release800 - 4400A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting200 - 400A
Position of connection for main current circuitFront side
Adjustment range short-term delayed short-circuit release0 - 0A
DIN rail (top hat rail) mounting optionalNo
Rated permanent current Iu400A
With integrated under voltage releaseNo
Integrated earth fault protectionYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
Number of poles4
Type of electrical connection of main circuitScrew connection
Rated voltage690 - 690V
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-AE400/250-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release

800 .. 4400A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

200 .. 400A

Position of connection for main current circuit

Front side

Adjustment range short-term delayed short-circuit release

0 .. 0A

DIN rail (top hat rail) mounting optional

Rated permanent current Iu

400A

With integrated under voltage release

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Type of electrical connection of main circuit

Screw connection

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

Complete device with protection unit

Related products