Technical specifications

Integrated earth fault protectionNo
Rated permanent current Iu400A
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release2400 - 4000A
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting320 - 400A
Motor drive integratedNo
Type of control elementRocker lever
Motor drive optionalYes
With switched-off indicatorNo
Number of poles3
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
With integrated under voltage releaseNo
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-A400

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Integrated earth fault protection

Rated permanent current Iu

400A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

2400 .. 4000A

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

320 .. 400A

Motor drive integrated

Type of control element

Rocker lever

Motor drive optional

With switched-off indicator

Number of poles

3

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

With integrated under voltage release

Complete device with protection unit