Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release0 - 0A
Rated permanent current Iu400A
Adjustment range undelayed short-circuit release800 - 4400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting200 - 400A
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Position of connection for main current circuitFront side
Type of control elementRocker lever
Device constructionBuilt-in device slide-in technique (withdrawable)
With switched-off indicatorNo
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
Complete device with protection unitYes
With integrated under voltage releaseNo
Type of electrical connection of main circuitScrew connection

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-AE400-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated permanent current Iu

400A

Adjustment range undelayed short-circuit release

800 .. 4400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

200 .. 400A

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Device construction

Built-in device slide-in technique (withdrawable)

With switched-off indicator

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

Complete device with protection unit

With integrated under voltage release

Type of electrical connection of main circuit

Screw connection

Related products