  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu400A
Overload release current setting200 - 400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Integrated earth fault protectionYes
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release800 - 4400A
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Number of poles3
Type of control elementRocker lever
Position of connection for main current circuitFront side
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP20
With integrated under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-AE400-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Overload release current setting

200 .. 400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

800 .. 4400A

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP20

With integrated under voltage release

DIN rail (top hat rail) mounting optional

Motor drive optional