Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu250A
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Overload release current setting200 - 250A
Adjustment range short-term delayed short-circuit release0 - 0A
Type of electrical connection of main circuitFrame clamp
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release1500 - 2500A
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Number of poles3
With integrated under voltage releaseNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive optionalYes
Motor drive integratedNo
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Type of control elementRocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A250-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Overload release current setting

200 .. 250A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of electrical connection of main circuit

Frame clamp

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

1500 .. 2500A

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of poles

3

With integrated under voltage release

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive optional

Motor drive integrated

Position of connection for main current circuit

Front side

Integrated earth fault protection

Type of control element

Rocker lever