Aleta.hr
Main Product Image

NZMN2-A250-SVE

Code: 1065419

ManufacturerEaton (Moeller)
Catalog number113246
Type
EAN code4015081127818

















Details

  • Low-voltage control systems
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release0 - 0A
Rated permanent current Iu250A
Adjustment range undelayed short-circuit release1500 - 2500A
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Complete device with protection unitYes
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device plug-in technique
Degree of protection (IP)IP20
Power loss58.1W
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Overload release current setting200 - 250A
Type of control elementRocker lever
With switched-off indicatorNo
Number of poles3
Rated voltage690 - 690V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-A250-SVE

Main Product Image

Details

  • Low-voltage control systems
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated permanent current Iu

250A

Adjustment range undelayed short-circuit release

1500 .. 2500A

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Complete device with protection unit

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device plug-in technique

Degree of protection (IP)

IP20

Power loss

58.1W

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Overload release current setting

200 .. 250A

Type of control element

Rocker lever

With switched-off indicator

Number of poles

3

Rated voltage

690 .. 690V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.