Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Overload release current setting400 - 500A
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Rated permanent current Iu500A
Position of connection for main current circuitFront side
Number of poles4
Motor drive integratedNo
Type of control elementRocker lever
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release0 - 0A
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Adjustment range undelayed short-circuit release6 - 10A
Number of auxiliary contacts as normally closed contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-A500/320

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Overload release current setting

400 .. 500A

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Rated permanent current Iu

500A

Position of connection for main current circuit

Front side

Number of poles

4

Motor drive integrated

Type of control element

Rocker lever

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Adjustment range undelayed short-circuit release

6 .. 10A

Number of auxiliary contacts as normally closed contact

0

Related products