Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu400A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting200 - 400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release800 - 4400A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Number of poles4
With switched-off indicatorNo
With integrated under voltage releaseNo
Complete device with protection unitYes
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-AE400-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

200 .. 400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

800 .. 4400A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Number of poles

4

With switched-off indicator

With integrated under voltage release

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional

Related products