Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Number of poles4
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu400A
Motor drive optionalYes
Motor drive integratedNo
Overload release current setting200 - 400A
Rated voltage690 - 690V
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release800 - 4400A
Complete device with protection unitYes
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-AE400-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of poles

4

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

400A

Motor drive optional

Motor drive integrated

Overload release current setting

200 .. 400A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

800 .. 4400A

Complete device with protection unit

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.