Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Overload release current setting320 - 400A
Rated permanent current Iu400A
Adjustment range undelayed short-circuit release2400 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of poles3
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
Complete device with protection unitYes
With switched-off indicatorNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-A400-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Overload release current setting

320 .. 400A

Rated permanent current Iu

400A

Adjustment range undelayed short-circuit release

2400 .. 4000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of poles

3

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

Complete device with protection unit

With switched-off indicator