Technical specifications

Rated permanent current Iu630A
Rated voltage690 - 690V
Overload release current setting315 - 630A
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of poles3
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Type of control elementRocker lever
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Adjustment range undelayed short-circuit release1260 - 5040A
Suitable for DIN rail (top hat rail) mountingNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-AE630-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

Rated voltage

690 .. 690V

Overload release current setting

315 .. 630A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Type of control element

Rocker lever

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Position of connection for main current circuit

Front side

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Adjustment range undelayed short-circuit release

1260 .. 5040A

Suitable for DIN rail (top hat rail) mounting