Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu630A
Overload release current setting315 - 630A
Device constructionBuilt-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Adjustment range undelayed short-circuit release1260 - 5040A
Adjustment range short-term delayed short-circuit release472 - 4410A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
Number of poles3
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VE630-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

630A

Overload release current setting

315 .. 630A

Device construction

Built-in device slide-in technique (withdrawable)

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range undelayed short-circuit release

1260 .. 5040A

Adjustment range short-term delayed short-circuit release

472 .. 4410A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Number of poles

3

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

Related products