Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated current25A
Built-in depth69.5mm
Suitable for flush-mounted installationNo
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of poles (total)2
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Frequency50 Hz
Over voltage category3
Connectable conductor cross section multi-wired1 - 25mm²
Number of protected poles1
Current limiting class3
Degree of protection (IP)IP20
Rated fault current0.03A
Rated voltage230V
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Surge current capacity0.25kA
Release characteristicB
Leakage current typeA
Concurrently switching neutral conductorYes
Pollution degree2
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PFL7-25/1N/B/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated current

25A

Built-in depth

69.5mm

Suitable for flush-mounted installation

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of poles (total)

2

Anti-nuisance tripping version

Connectable conductor cross section solid-core

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Frequency

50 Hz

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of protected poles

1

Current limiting class

3

Degree of protection (IP)

IP20

Rated fault current

0.03A

Rated voltage

230V

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Surge current capacity

0.25kA

Release characteristic

B

Leakage current type

A

Concurrently switching neutral conductor

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.