Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Device constructionBuilt-in device plug-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu50A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release300 - 500A
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Number of poles3
Overload release current setting40 - 50A
Type of control elementRocker lever
Motor drive optionalNo
Complete device with protection unitYes
With integrated under voltage releaseNo
With switched-off indicatorNo
Motor drive integratedNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-A50-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Device construction

Built-in device plug-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

50A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

300 .. 500A

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Overload release current setting

40 .. 50A

Type of control element

Rocker lever

Motor drive optional

Complete device with protection unit

With integrated under voltage release

With switched-off indicator

Motor drive integrated

Degree of protection (IP)

IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.