Technical specifications

Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting50 - 63A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device plug-in technique
Rated permanent current Iu63A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Number of poles3
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Motor drive optionalNo
Motor drive integratedNo
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release380 - 630A
With switched-off indicatorNo
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Type of control elementRocker lever
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH1-A63-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

50 .. 63A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device plug-in technique

Rated permanent current Iu

63A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Number of poles

3

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Motor drive integrated

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

380 .. 630A

With switched-off indicator

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Related products