Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device plug-in technique
Rated permanent current Iu80A
Type of electrical connection of main circuitFrame clamp
DIN rail (top hat rail) mounting optionalYes
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release480 - 800A
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release0 - 0A
With integrated under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting63 - 80A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
With switched-off indicatorNo
Number of poles3
Type of control elementRocker lever
Motor drive optionalNo
Degree of protection (IP)IP20
Motor drive integratedNo
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-A80-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device plug-in technique

Rated permanent current Iu

80A

Type of electrical connection of main circuit

Frame clamp

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

480 .. 800A

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

With integrated under voltage release

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

63 .. 80A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

With switched-off indicator

Number of poles

3

Type of control element

Rocker lever

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Complete device with protection unit

Related products