Technical specifications

Rated permanent current Iu250A
Overload release current setting125 - 250A
Rated voltage1000 - 1000V
Adjustment range short-term delayed short-circuit release250 - 2500A
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release3000 - 3000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
With switched-off indicatorNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Type of control elementRocker lever
Number of poles3
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-VE250-S1

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Overload release current setting

125 .. 250A

Rated voltage

1000 .. 1000V

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

3000 .. 3000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

With switched-off indicator

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Type of control element

Rocker lever

Number of poles

3

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive integrated

Motor drive optional

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release