Technical specifications

Rated permanent current Iu500A
Adjustment range undelayed short-circuit release6 - 10A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Rated voltage690 - 690V
Integrated earth fault protectionNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Overload release current setting400 - 500A
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Number of poles4
Position of connection for main current circuitFront side
Type of control elementRocker lever
Motor drive integratedNo
Degree of protection (IP)IP20
Complete device with protection unitYes
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
With integrated under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-A500-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

500A

Adjustment range undelayed short-circuit release

6 .. 10A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated voltage

690 .. 690V

Integrated earth fault protection

Device construction

Built-in device slide-in technique (withdrawable)

Overload release current setting

400 .. 500A

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of poles

4

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Motor drive integrated

Degree of protection (IP)

IP20

Complete device with protection unit

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Motor drive optional

With integrated under voltage release