Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting400 - 500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release6 - 10A
Type of electrical connection of main circuitScrew connection
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Rated permanent current Iu500A
With switched-off indicatorNo
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Complete device with protection unitYes
Number of auxiliary contacts as normally open contact0
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
Number of poles4
Device constructionBuilt-in device slide-in technique (withdrawable)
Motor drive integratedNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-A500/320-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

400 .. 500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

6 .. 10A

Type of electrical connection of main circuit

Screw connection

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Rated permanent current Iu

500A

With switched-off indicator

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Motor drive optional

Position of connection for main current circuit

Front side

Complete device with protection unit

Number of auxiliary contacts as normally open contact

0

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Device construction

Built-in device slide-in technique (withdrawable)

Motor drive integrated

Degree of protection (IP)

IP20

Related products