Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu320A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
Rated voltage690 - 690V
Device constructionBuilt-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release1920 - 19200A
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting250 - 320A
Number of auxiliary contacts as normally closed contact0
Number of poles4
Type of control elementRocker lever
With integrated under voltage releaseNo
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes
Complete device with protection unitYes
Integrated earth fault protectionNo
With switched-off indicatorNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-A320-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

320A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

Rated voltage

690 .. 690V

Device construction

Built-in device slide-in technique (withdrawable)

Adjustment range undelayed short-circuit release

1920 .. 19200A

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

250 .. 320A

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Type of control element

Rocker lever

With integrated under voltage release

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional

Complete device with protection unit

Integrated earth fault protection

With switched-off indicator

Related products