Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •5 KOM
- •EATON
Technical specifications
Related products
DIL-SWD-32-001

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 5 KOM
- EATON
Technical specifications
Width
45mm
Number of digital outputs
1
Depth
72mm
Input current at signal 1
3mA
Number of digital inputs
2
Suitable for safety functions
Height
38mm
Time delay at signal exchange
10 .. 84ms
Voltage type of supply voltage
DC
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for LON
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIBUS
Type of voltage (input voltage)
DC
Supporting protocol for TCP/IP
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
With optical interface
Number of HW-interfaces other
1
Supporting protocol for CAN
Fieldbus connection over separate bus coupler possible
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Output current
0.5A
Explosion safety category for dust
None
Supporting protocol for INTERBUS
Rail mounting possible
Type of digital output
None
Supporting protocol for DeviceNet
Explosion safety category for gas
None
Type of electric connection
Spring clamp connection
Supporting protocol for Modbus
Supporting protocol for ASI
Short-circuit protection, outputs available
Supporting protocol for KNX
System accessory
Appendant operation agent (Ex ib)
Degree of protection (IP)
IP20
Number of HW-interfaces Wireless
0
Number of interfaces PROFINET
0
Radio standard Bluetooth
Supporting protocol for EtherNet/IP
Rack-assembly possible
Performance level according to EN ISO 13849-1
None
Wall mounting/direct mounting
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Front built-in possible
Supporting protocol for INTERBUS-Safety
Radio standard Wi-Fi 802.11
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
IO link master
Supporting protocol for SERCOS
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
15 .. 15V
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Appendant operation agent (Ex ia)
Type of output voltage
DC
Digital inputs configurable
SIL according to IEC 61508
None
Permitted voltage at output
20.4 .. 28.8V
Certified for UL hazardous location class III
Permitted voltage at input
15 .. 15V
Supporting protocol for EtherCAT
Radio standard GPRS
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Radio standard UMTS
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location division 1
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location division 2
Certified for UL hazardous location group E (metal dusts)
Radio standard GSM
Certified for UL hazardous location group F (carbonaceous dusts)
Digital outputs configurable